Cell viability and probe-cell membrane interactions of XR1 glial cells imaged by atomic force microscopy.
Schaus SS
,
Henderson ER
.
???displayArticle.abstract???
As atomic force microscopy (AFM) imaging of live specimens becomes more commonplace, at least two important questions arise: 1) do live specimens remain viable during and after AFM, and 2) is there transfer of membrane components from the cell to the AFM probe during probe-membrane interactions? We imaged live XR1 glial cells in culture by single- or dual-pass contact or tapping-mode AFM, examined cell viability at various postimaging times, and report that AFM-imaged live XR1 cells remained viable up to 48 h postimaging and that cell death rates did not increase. To determine if nonlethal, transient interactions between the AFM probe and cell membrane led to transfer of XR1 cell membrane phospholipid components on the probe, we treated the scanned probes with the lipid-binding fluorophore FM 1-43. Confocal microscopy revealed that phospholipid membrane components did accumulate on the probe, and to a generally greater extent during contact-mode imaging than during tapping-mode imaging. Moreover, membrane accumulations on the probe were greater when live XR1 cells were damaged or perturbed, yet membrane did not accumulate in fluorescently detectable quantities during repeated "force curves" during control experiments. Taken together, our data indicate that although AFM imaging of live cells in culture does not affect long-term cell viability, there are substantial probe-membrane interactions that lead to transfer of membrane components to the probe.
Barbee,
Shear stress-induced reorganization of the surface topography of living endothelial cells imaged by atomic force microscopy.
1994, Pubmed
Barbee,
Shear stress-induced reorganization of the surface topography of living endothelial cells imaged by atomic force microscopy.
1994,
Pubmed
Beckmann,
Atomic force microscopy of peritoneal macrophages after particle phagocytosis.
1994,
Pubmed
Betz,
Intracellular movements of fluorescently labeled synaptic vesicles in frog motor nerve terminals during nerve stimulation.
1992,
Pubmed
Betz,
Optical analysis of synaptic vesicle recycling at the frog neuromuscular junction.
1992,
Pubmed
Betz,
Activity-dependent fluorescent staining and destaining of living vertebrate motor nerve terminals.
1992,
Pubmed
Binnig,
Atomic force microscope.
1986,
Pubmed
Bonfiglio,
Subcellular details of early events of differentiation induced by retinoic acid in human neuroblastoma cells detected by atomic force microscope.
1995,
Pubmed
Braunstein,
Structure and activation dynamics of RBL-2H3 cells observed with scanning force microscopy.
1994,
Pubmed
Chang,
Cytoskeleton of living, unstained cells imaged by scanning force microscopy.
1993,
Pubmed
Fritz,
Granula motion and membrane spreading during activation of human platelets imaged by atomic force microscopy.
1994,
Pubmed
Haydon,
Membrane deformation of living glial cells using atomic force microscopy.
1996,
Pubmed
Henderson,
Actin filament dynamics in living glial cells imaged by atomic force microscopy.
1992,
Pubmed
,
Xenbase
Hoh,
Surface morphology and mechanical properties of MDCK monolayers by atomic force microscopy.
1994,
Pubmed
Häberle,
In situ investigations of single living cells infected by viruses.
1992,
Pubmed
Hörber,
Investigation of living cells in the nanometer regime with the scanning force microscope.
1992,
Pubmed
Kasas,
Observation of living cells using the atomic force microscope.
1993,
Pubmed
Lal,
Imaging real-time neurite outgrowth and cytoskeletal reorganization with an atomic force microscope.
1995,
Pubmed
Le Grimellec,
Imaging of the membrane surface of MDCK cells by atomic force microscopy.
1994,
Pubmed
Meffert,
Nitric oxide stimulates Ca(2+)-independent synaptic vesicle release.
1994,
Pubmed
Oberleithner,
Imaging the lamellipodium of migrating epithelial cells in vivo by atomic force microscopy.
1993,
Pubmed
Oberleithner,
Living renal epithelial cells imaged by atomic force microscopy.
1994,
Pubmed
Putman,
Viscoelasticity of living cells allows high resolution imaging by tapping mode atomic force microscopy.
1994,
Pubmed
Radmacher,
Imaging soft samples with the atomic force microscope: gelatin in water and propanol.
1995,
Pubmed
Ricci,
Scanning force microscopy on live cultured cells: imaging and force-versus-distance investigations.
1994,
Pubmed
Sakaguchi,
Growth cone interactions with a glial cell line from embryonic Xenopus retina.
1989,
Pubmed
,
Xenbase
Schneider,
Surface dynamics in living acinar cells imaged by atomic force microscopy: identification of plasma membrane structures involved in exocytosis.
1997,
Pubmed
Schoenenberger,
Slow cellular dynamics in MDCK and R5 cells monitored by time-lapse atomic force microscopy.
1994,
Pubmed
Schwab,
Polarized ion transport during migration of transformed Madin-Darby canine kidney cells.
1995,
Pubmed
Shroff,
Dynamic micromechanical properties of cultured rat atrial myocytes measured by atomic force microscopy.
1995,
Pubmed
Spudich,
Large secretory structures at the cell surface imaged with scanning force microscopy.
1995,
Pubmed
Tao,
Measuring the microelastic properties of biological material.
1992,
Pubmed
Vesenka,
Humidity effects on atomic force microscopy of gold-labeled DNA on mica.
1993,
Pubmed
Vesenka,
Combining optical and atomic force microscopy for life sciences research.
1995,
Pubmed
,
Xenbase